33kV GO AB Switch 400-800 Amps Polymer 9 Post Insulator 34MM FRP
33kV GO AB Switch 400-800 Amps Polymer 9 Post Insulator 34MM FRP

33kV GO AB Switch 400-800 Amps Polymer 9 Post Insulator 34MM FRP

33kV GO AB Switch 400-800 Amps Polymer 9 Post Insulator 34MM FRP Specification

  • Coating Type
  • Hot Dip Galvanized
  • Thermal Conductivity
  • Low (Insulator, FRP)
  • Installation Guideline
  • Outdoor Pole/Structure Mounting, Follow standard electrical safety norms
  • Feature
  • Corrosion Resistant, UV Resistant, High Mechanical Strength, Maintenance Free
  • Density
  • Gram per cubic centimeter(g/cm3)
  • Size
  • Standard for 33kV, pole mounting; custom sizes available
  • Layer
  • Single layer construction, with composite material insulator
  • Surface Treatment
  • Hot Dip Galvanized (Metal parts), Weather Resistant (Insulators)
  • Product Type
  • GO AB (Gang Operated Air Break) Switch
  • Material
  • Galvanized Steel, Polymer Insulator, FRP Rod (34MM)
  • Rated Voltage
  • 33kV
  • Tensile Strength
  • >600 MPa (FRP Rod), >300 MPa (Steel)
  • Width
  • As per standard design for 33kV switches
  • Thickness
  • 34MM FRP Rod
  • Application
  • Medium & High Voltage Electrical Distribution Lines
  • Breakdown Voltage
  • >= 80 kV peak (Insulator)
  • Heat Conductivity
  • Low (Polymer and FRP materials)
  • Color
  • Grey (Metal), Black (Polymer Insulator)
  • Max Withstanding Temperature
  • -40C to +120C
  • Operating Mechanism
  • Manual/Motorized (optional)
  • Phase
  • 3 Phase
  • Packing
  • Wooden Crate/Box Packing
  • Mechanical Endurance
  • 2000 operations minimum
  • Impulse Withstand Voltage
  • 170kVp
  • FRP Rod Diameter
  • 34MM
  • Corona Extinction Voltage
  • >42kV
  • Current Rating
  • 400-800 Amps
  • Arcing Horns
  • Provided for additional arc protection
  • Power Frequency Withstand Voltage
  • 70kV (1 min)
  • Insulator Creepage Distance
  • 900mm or as per IEC/IS standards
  • Earthing Terminal
  • Provided as per standard
  • Number of Insulators
  • 9 Post Polymer Insulators per set
  • Connection Type
  • Horizontal/Vertical Mounting Possible
  • Mounting Type
  • Outdoor, Structure/Pole Mounting
 
 

About 33kV GO AB Switch 400-800 Amps Polymer 9 Post Insulator 34MM FRP



The latest 33kV GO AB Switch 400-800 Amps Polymer 9 Post Insulator 34MM FRP stands out as a dominant force in medium and high voltage electrical distribution lines. Acclaimed for its potent mechanical endurance and enviable resilience, it features 9 polymer insulators per set, a corrosion-resistant galvanized steel structure, and a robust 34MM FRP rod. Highly cost-effective, this switch offers high current capacity, superior dielectric performance, and outstanding weather and UV resistance. Its maintenance-free design, multiple mounting options, and strong safety features make it ideal for demanding outdoor applications.

Versatile Usage & Distinctive Advantages

This GO AB Switch excels in outdoor pole and structure mounting, targeted for medium and high voltage distribution lines. Its powerful 400-800 Amps current rating and advanced polymer insulator configuration ensure longevity and operational safety. The major competitive advantages include high mechanical strength, UV and corrosion resistance, and minimal maintenance requirements. Installation is straightforward, aligning with standard electrical safety norms, making it a top choice among distributors and utilities seeking reliability and innovation.


Reliable Supply, Robust Packaging & Global Reach

Backed by dependable supply ability, each unit is meticulously packed in secure wooden crates or boxes to ensure safe shipment. The packaging guarantees the switch's integrity during transport and handling. With a strong market value, our GO AB Switch has achieved significant demand across international markets. Timely shipment and tailored packaging support smooth export operations, while the product's durability and compliance with international standards support its growing presence and reputation worldwide.


FAQ's of 33kV GO AB Switch 400-800 Amps Polymer 9 Post Insulator 34MM FRP:


Q: How does the 33kV GO AB Switch enhance safety in electrical distribution lines?

A: The switch features polymer insulators, arcing horns, and robust earthing terminals to protect against electrical faults and arc-related hazards. Its mechanical endurance and UV/corrosion resistance contribute to dependable and safe operation outdoors.

Q: What is the installation process for the 33kV GO AB Switch?

A: Installation involves mounting the switch on poles or structures using provided hardware and following standard electrical safety guidelines. Both manual and motorized operating mechanisms can be selected to suit operational requirements.

Q: Where is this GO AB Switch most suitable for use?

A: This switch is ideal for medium and high voltage outdoor electrical distribution lines, especially in environments demanding high reliability, weather resistance, and minimal maintenance.

Q: What benefits do the polymer insulators and FRP rod provide?

A: The polymer insulators and FRP rod offer superior mechanical strength, high dielectric resistance, and low thermal conductivity. These properties ensure excellent performance under diverse weather conditions and extend service life.

Q: When should the switch be maintained or inspected?

A: Its maintenance-free design reduces the need for regular upkeep. However, periodic inspections, as per industry standards, are recommended to ensure all components remain in optimal working condition.

Q: How is the switch packaged before shipment?

A: Each switch is securely packed in wooden crates or box packing to protect the product during shipment and ensure safe delivery to installation sites, supporting global export requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Polymer Insulator Category

33 kV Pin Polymer Insulator 34 mm FRP

33 kV Pin Polymer Insulator 34 mm FRP

Width : Approx. 130 mm (Shed diameter)

Max Withstanding Temperature : 40C to +120C

Product Type : Pin Polymer Insulator

Surface Treatment : UV resistant, Hydrophobic Silicon Rubber Surface

Breakdown Voltage : > 200 kV (Impulse withstand)

Color : Gray

33 kV 1250 Amps Polymer Insulator

33 kV 1250 Amps Polymer Insulator

Width : 150 mm (Approx. depends on product design)

Max Withstanding Temperature : 40C to +90C

Product Type : Polymer Line Post Insulator

Surface Treatment : UV resistant, hydrophobic silicone coating

Breakdown Voltage : >250 kV (Impulse withstand)

Color : Gray

33 kV Disc Polymer Insulator T-I

33 kV Disc Polymer Insulator T-I

Width : Approx. 210 mm (Disc Diameter)

Max Withstanding Temperature : 40C to 120C

Product Type : Disc Polymer Insulator (TI Type)

Surface Treatment : Hydrophobic silicone coated

Breakdown Voltage : >110 kV

Color : Grey

66 kV Disc Polymer Insulator B And S

66 kV Disc Polymer Insulator B And S

Width : Approx. 180250 mm (shed diameter)

Max Withstanding Temperature : 40C to +120C

Product Type : Disc Polymer Insulator (Ball and Socket Type)

Surface Treatment : Antiaging silicone coating

Breakdown Voltage : Greater than 200 kV (power frequency dry)

Color : Gray



arrow